Teilenummer POWERWARE9120-1000VA

Uninterruptible Power Supply

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
powerware9120-1000va
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
015644077

Informationen zum Teil
Storage temp: m15.0/p40.0 degrees c; input connection: iec 320/10a; output connection: 4 x iec 320/10a; capacity: 1000 va

NSN
Nationale Bestandsnummer:
6130-01-564-4077 6130015644077
TXT
Beschreibung:
Uninterruptible Power Supply
INC
INC
Artikelname-Code:
67374
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.142 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.449 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.102 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
3000.0 meters
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
230.0 ac pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
208.0 ac volts single power output and 240.0 ac volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.0/+40.0 degrees celsius
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Receptacle, electrical single operating power rqmt
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
8.0

Ähnlich Uninterruptible Power Supplies

« Converters Electrical Nonrotating {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken