Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radio Frequency Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.960 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.750 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-54.0 to 71.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-62.0 to 125.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Bmews radar upgrade
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Module
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
50.0 megahertz operating channel and 850.0 megahertz operating channel
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
25.0 decibels
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 single voltage
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Two-stage universal amplifier, low vswr and noise figure, utilizes power feedback techniques which result in high reverse isolation and excellent input/output return loss