Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
r123-701-2040
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Resolver
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, stainless
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Standard round d
MRC:
The length of a straight line which passes through the center of a shoulder,and terminates at the circumference.AAVH
Shoulder Diameter:
Between 1.9850 inches and 1.9900 inches
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
Between 0.5900 inches and 0.6000 inches
Second Shoulder Diameter:
Between 1.9985 inches and 1.9995 inches
Second Shoulder Length:
0.1700 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.7870 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
Between 2.2490 inches and 2.2500 inches
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.2500 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.9900 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.2402 inches single shaft and 0.2405 inches single shaft
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.6930 inches single shaft and 0.7190 inches single shaft
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
23
MRC:
The value of the primary excitation voltage for which the stator is rated,expressed in volts.AJSN
Stator Input Voltage Rating In Volts:
10.0
MRC:
The value of the primary excitation current for which the stator is rated,with rotor /secondary/ circuit open.AJSP
Stator Input Current Rating:
16.0 milliamperes
MRC:
The value of the primary /electrical/ excitation power for which the stator is rated.AJSQ
Stator Input Electrical Power Rating:
11.0 milliwatts
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The resistance /r/ part of the rotor impedance with the stator open /zro/,expressed in ohms.AJSW
Zro Resistance In Ohms:
37.00
MRC:
The resistance /r/ part of the stator impedance with the rotor open /zso/,expressed in ohms.AJSY
Zso Resistance In Ohms:
41.00
MRC:
The opposition that the rotor offers to the flow of the direct current,expressed in ohms.AJTS
Rotor Dc Resistance In Ohms:
30.00
MRC:
The opposition that the stator offers to the flow of direct current,expressed in ohms.AJTT
Stator Dc Resistance In Ohms:
11.00
MRC:
The variation of the transformation ratio for all possible combinations of stator,rotor,and compensating windings,expressed in percent.AJTW
Transformation Ratio Equality In Percent:
0.1
MRC:
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.AJVF
Phase Shift Angle In Deg:
0.933 input to output
MRC:
The maximum voltage,without harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVG
Maximum Fundamental Null Voltage In Millivolts Per Volt:
5.00 output
MRC:
The maximum voltage,including harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVH
Maximum Total Null Voltage Output In Millivolts Per Volt:
10.00
MRC:
The deviation from 90 degrees perpendicularity of the secondary winding,when excitation is applied to one of the primary windings,expressed in minutes.AJVJ
Interaxis Error Angular Range In Minutes:
-2.5/+2.5
MRC:
A measurement of the longest dimension of a pilot,in distinction from width.AJWQ
Pilot Length:
0.0580 inches
Shoulder Length:
0.2520 inches
Aft Of First Flange Diameter:
Between 1.9985 inches and 1.9995 inches
Mounting Surface To Terminal End Distance:
Between 3.9230 inches and 3.9380 inches
MRC:
A designation distinguishing one group of shaft thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYY
Shaft Thread Series Designator:
Unf single shaft
MRC:
The direction of the shaft thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AKAF
Shaft Thread Direction:
Right-hand single shaft
MRC:
A numeric-alpha designator indicating the ptich diameter tolerance,and an external or internal shaft thread.AKAN
Shaft Thread Class:
2a single shaft
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Rear
MRC:
A measurement of the extent of the shaft threads measured on a line parallel to the longitudinal axis.CQWQ
Shaft Thread Length:
0.3100 inches single shaft
MRC:
The reactance (x) part of the rotor impedance with the stator open (zro).CQXQ
Plus J Zro Reactance In Ohms:
59.00
MRC:
The reactance (x) part of the stator impedance with the rotor open (zso),expressed in ohms.CRGZ
Plus J Zso Reactance In Ohms:
617.00
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, threaded single shaft
MRC:
The ratio of the output voltage to the input voltage at maximum coupling.CSJY
Transformation Ratio:
0.990 rotor to stator
MRC:
The length of a straight line passing through the center of the shaft threaded portion,with terminated points at the circumference.CWBH
Shaft Thread Size:
0.250 inches single shaft
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 wire lead