Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Rota Electro-mechanical Actuator
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Insulated wire lead
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit and 165.0 degrees fahrenheit
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
3.580 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
14.370 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
5.760 inches
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
11.0 and 17.0
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
50000.0 feet
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise and counterclockwise
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
9.0
MRC:
The means by which the braking action is applied.ATWS
Braking Method:
Electric
MRC:
The measurement of rotation,expressed in degrees.AWQL
Rotation In Deg:
Between 74.0 and 76.0
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
The means used to reset the thermal protector.AWQP
Thermal Protector Reset Method:
Manual
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Included
MRC:
An indication of the rotation of the angular shaft.AWTZ
Angular Shaft Rotation:
Limited
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
80.0 seconds on and 5.0 minutes off
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
25.0 and 29.0
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81039-r6116-5 professional/industrial association specification