Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Indicating Temperature Control
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-100.0/+600.0 degrees fahrenheit
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
240.0 ac
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
5.4
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Bottom
MRC:
The minimum and maximum operating limits of the item.ASXT
Operating Range:
Minus 100 to plus 600 degrees f
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
The maximum rated power that an item can safely consume or provide,measured in watts.AZQH
Maximum Wattage Rating In Watts:
350.0
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
4 wire lead
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
6.625 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
4.125 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
4.500 inches
MRC:
The intelligence data the item is capable of handling.CKQY
Intelligence Data Handling Capability:
Temperature transmitting automatic
MRC:
The means provided to indicate data.CKQZ
Indication Method:
Transmitting dial
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0