Teilenummer RE60G1R80

Induct Wire Wound Fixed Resistor

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
re60g1r80
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
013585951
NSN
Nationale Bestandsnummer:
5905-01-358-5951 5905013585951
TXT
Beschreibung:
Induct Wire Wound Fixed Resistor
INC
INC
Artikelname-Code:
37403
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-50.0/+50.0
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
1.800 ohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-1.000/+1.000
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.125 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.490 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
5.000 heat sink
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Axial terminal (s)
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-r-18546 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).