Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Three filtered functions
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Interfere Filter				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.390 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						3.190 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						2.750 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						2.120 inches 					
				 
							
					
						MRC:
						The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
					 
					
						Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
					
					
						1.875 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-55.0/+85.0 degrees celsius					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 1st radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 3rd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 1st radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 3rd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 1st radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 2nd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 3rd radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						10.0 1st radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						10.0 2nd radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						10.0 3rd radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						500.0 millivolts dc 1st radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						500.0 millivolts dc 2nd radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						500.0 millivolts dc 3rd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 1st radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 3rd radio interference					
				 
							
					
						MRC:
						The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
					 
					
						Input Terminal Manufacturer Code:
					
					
						96906					
				 
							
					
						MRC:
						The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
					 
					
						Input Terminal Identification:
					
					
						Ms3102r-20-4p					
				 
							
					
						MRC:
						The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
					 
					
						Maximum Tempurature Rise:
					
					
						25.0 degrees celsius					
				 
							
					
						MRC:
						A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
					 
					
						Mounting Facility Screw Thread Series Designator:
					
					
						Unc					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						4 threaded hole					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 connector,  receptacle input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 turret ground 3rd function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						3 turret output 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						240.0 volts ac 2nd radio interference 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						240.0 volts ac 3rd radio interference 3rd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						240.0 volts ac 1st radio interference 1st function					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.112 inches					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.CRST
					 
					
						Body Surface Treatment:
					
					
						Tin					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular terminal/terminals on opposite surfaces