Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Transmissio Line				
			 
			
							
										
					
						MRC:
						A measurement of the longest dimension of an item,in distinction from width.AAJU
					 
					
						Overall Length:
					
					
						7.500 inches					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an item,and terminates at the outside circumference.ABHE
					 
					
						Outside Diameter:
					
					
						0.142 inches 					
				 
							
					
						MRC:
						The wire gage designation and the gage number used to describe the conductor size.ACVL
					 
					
						Conductor Size:
					
					
						18.0 awg					
				 
							
					
						MRC:
						The amount of electrical energy that can be dissipated.AJDB
					 
					
						Power Rating:
					
					
						500.0 watts average					
				 
							
					
						MRC:
						The reactance-resistance complex value which must be matched by the transmission line and termination to achieve lowest standing wave ratio,expressed in ohms.AJDD
					 
					
						Characteristic Impedance In Ohms:
					
					
						50.0					
				 
							
					
						MRC:
						The specification,standard,or the number or symbol of the manufacturer used to identify the termination.AJDF
					 
					
						Termination Identification:
					
					
						2887937-1					
				 
							
					
						MRC:
						The specification,standard,or the number or symbol of the manufacturer used to identify the termination.AJDF
					 
					
						Termination Identification:
					
					
						2888190-1					
				 
							
					
						MRC:
						The number of electrical conductors included on the item.AMQN
					 
					
						Conductor Quantity:
					
					
						1					
				 
							
					
						MRC:
						The element,compound,or mixture of which the conductor is fabricated,excluding any surface treatment.APYQ
					 
					
						Conductor Material:
					
					
						Steel wire, qq-w-345, type 1					
				 
							
					
						MRC:
						The electrical capacitance measured between two specified points on the item,expressed in picofarads per unit length.APZA
					 
					
						Capacitance In Picofarads Per Unit Length:
					
					
						29.1 per foot					
				 
							
					
						MRC:
						The voltage rating at which the item is designed to operate.APZB
					 
					
						Operating Voltage Rating:
					
					
						5000.0 volts					
				 
							
					
						MRC:
						An indication of whether or not the item includes an outer conductor.APZC
					 
					
						Outer Conductor:
					
					
						Included					
				 
							
					
						MRC:
						The physical configuration of the insulation spacer.APZD
					 
					
						Insulation Spacer Shape:
					
					
						Round					
				 
							
					
						MRC:
						The element,compound,or mixture from which the insulation spacer is fabricated,excluding any surface treatment.AQAZ
					 
					
						Insulation Spacer Material:
					
					
						Plastic,  polytetrafluoroethylene					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the insulation spacer,and terminates at the outside circumference.AQBA
					 
					
						Insulation Spacer Outside Diameter:
					
					
						0.118 inches 					
				 
							
					
						MRC:
						The name of the government agency or commercial organization controlling the termination.AQBB
					 
					
						Termination Controlling Agency:
					
					
						Naval ordnance systems command					
				 
							
					
						MRC:
						An indication of whether or not a terminal fitting/s/ is included.AQBD
					 
					
						Terminal Fitting:
					
					
						Included					
				 
							
					
						MRC:
						Indicates the type of conductor the item is designed to accommodate.AQCE
					 
					
						Accommodated Conductor Type:
					
					
						Coaxial					
				 
							
					
						MRC:
						Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the conductor.AQRW
					 
					
						Conductor Surface Treatment:
					
					
						Copper and silver plated, astm-b298, class c					
				 
							
					
						MRC:
						The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
					 
					
						Material:
					
					
						Copper, astm-b75					
				 
							
					
						MRC:
						Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
					 
					
						Surface Treatment:
					
					
						Tin plated,  mil-t-10727,  type 1