Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Dose rate ranges 0-5, 0-50, 0-500 mr/hr, 0-5, 0-50, 0-500 r/hr; integrate ranges 0-5, 0-50, 0-500 mr; operating temp range 0-60 degrees c
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radiacmeter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means of attaching the item.ADJH
Mounting Method:
Portable
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Alpha rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
X-rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Ionization chamber
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+500.0 roentgens
MRC:
The minimum and maximum number of single responses per minute.APPK
Count Range Per Minute:
Not rated
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Not rated
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
+6.500/+1200.000 kev
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
3.4 dc
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
3.4