Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
rt1007a1-4in160t190degf
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Temperature Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Bronze
First End Flange Outside Diameter:
9.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Plain face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Round w/ bolt holes
MRC:
A measurement of the smallest dimension of the first end flange, in distinction from length or width.ACKU
First End Flange Thickness:
0.688 inches
MRC:
The number of bolt holes provided on the item.ACKZ
First End Bolt Hole Quantity:
8
MRC:
The length of a straight line which passes through the center of a bolt hole,and terminates at the circumference.ACLA
First End Bolt Hole Diameter:
0.750 inches
First End Bolt Circle Diameter:
7.500 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
An indication of the action of a two-way valve.AEVM
Two-way Valve Action:
Reverse acting
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
480.000 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
24.000 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
1.250 inches
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Not adjustable
MRC:
The basic design type of the thermostatic element used in transmitting the temperature of a liquid or gas.AEWJ
Thermostatic Element:
Liquid immersion type
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between 160.0 degrees fahrenheit and 190.0 degrees fahrenheit