Teilenummer RV2

Non Wire Wound Variable Resistor

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
rv2
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
002843798
NSN
Nationale Bestandsnummer:
5905-00-284-3798 5905002843798
TXT
Beschreibung:
Non Wire Wound Variable Resistor
INC
INC
Artikelname-Code:
37406
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.250 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.938 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
The maximum amount of turning force required to initiate the actuator movement.AEFK
Maximum Starting Torque:
1.00 inch-ounces
MRC:
The maximum amount of force requred to maintain actuator movement.AEFL
Maximum Running Torque:
0.50 inch-ounces
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
10.000 kilohms single section
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-1.00/+1.00 single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
4.0 free air single section
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
Single section independent linearity
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0/+5.0 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 solder stud