Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Transmiss Switch				
			 
			
							
										
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						0.0 gigahertz  1st frequency insertion loss reference and 8.0 gigahertz  1st frequency insertion loss reference					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						0.0 gigahertz  1st frequency voltage standing wave ratio and 8.0 gigahertz  1st frequency voltage standing wave ratio					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						13.0 gigahertz  3rd frequency insertion loss reference and 18.0 gigahertz  3rd frequency insertion loss reference					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						13.0 gigahertz  3rd frequency voltage standing wave ratio and 18.0 gigahertz  3rd frequency voltage standing wave ratio					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						7.5 gigahertz  2nd frequency insertion loss reference and 13.0 gigahertz  2nd frequency insertion loss reference					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						8.0 gigahertz  2nd frequency voltage standing wave ratio and 13.0 gigahertz  2nd frequency voltage standing wave ratio					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						7.5 gigahertz   and 13.0 gigahertz  2nd frequency insertion loss reference					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						8.0 gigahertz   and 13.0 gigahertz  2nd frequency voltage standing wave ratio					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						0.0 gigahertz   and 8.0 gigahertz  1st frequency voltage standing wave ratio					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						0.0 gigahertz   and 8.0 gigahertz  1st frequency insertion loss reference					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						13.0 gigahertz   and 18.0 gigahertz  3rd frequency voltage standing wave ratio					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						13.0 gigahertz   and 18.0 gigahertz  3rd frequency insertion loss reference					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-54.0/+163.0 degrees fahrenheit					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-54.0 to 163.0 degrees fahrenheit					
				 
							
					
						MRC:
						The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
					 
					
						Actuator Current Type And Rating In Amps:
					
					
						0.3 dc 					
				 
							
					
						MRC:
						The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
					 
					
						Actuator Voltage In Volts:
					
					
						28.0 					
				 
							
					
						MRC:
						The time required for switching between any two adjacent positions.AKPP
					 
					
						Switching Time:
					
					
						20.0 milliseconds					
				 
							
					
						MRC:
						The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
					 
					
						Switch Return Mechanism Type:
					
					
						Latching					
				 
							
					
						MRC:
						The maximum radio frequency voltage that the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration.AKQA
					 
					
						Rf Maximum Voltage Rating:
					
					
						30.0 volts peak					
				 
							
					
						MRC:
						The number of coupling positions provided.AKRC
					 
					
						Coupling Position Quantity:
					
					
						3					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						3 plug,  coaxial