Teilenummer SG343UPM15A

Pulse Generator

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
sg343upm15a
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
008923313
NSN
Nationale Bestandsnummer:
6625-00-892-3313 6625008923313
TXT
Beschreibung:
Pulse Generator
INC
INC
Artikelname-Code:
00411
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
11.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
14.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+131.0 degrees fahrenheit
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
Sg343upm15a-80058
MRC:
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.AJVF
Phase Shift Angle In Deg:
Any acceptable
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
Not rated
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Electron tube
MRC:
The shift of the frequency of the item.BHSZ
Frequency Shift:
Any acceptable
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 kilohertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
50.0 hertz operating channel err-100
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Continuous
MRC:
The amount of allowable variation relative to a specified frequency level,expressed in decibels.BHTG
Variation Frequency Rating In Decibels:
Any acceptable
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
300.0 watts output
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
Not rated
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
Not rated
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
Not rated
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
250.000 nanoseconds operating channel err-100
MRC:
The length of time it takes the pulse to rise per channel.BHTQ
Pulse Rise Time Per Channel:
50.000 nanoseconds operating channel err-100
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
2.000 microseconds operating channel err-100
MRC:
The length of time it takes the trailing edge of the pulse to fall per channel.BHTR
Pulse Decay Time Per Channel:
30.000 microseconds operating channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Any acceptable
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
10.000 kilopulses per second operating channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
50.000 pulses per second operating channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
Not rated
MRC:
Indicates the type of pulse modulation per channel.BHTY
Pulse Modulation Type Per Channel:
Amplitude operating channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel pulse, amplitude
MRC:
The limits of calbration,expressed in percent.BJBH
Calibrated Tolerance In Percent:
-5.0/+5.0
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Sawtooth
MRC:
The maximum time an item will continuously run,expressed in hours.BJBM
Maximum Continuous Operating Time In Hours:
Not rated
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
1000.0 single voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 single voltage
MRC:
A designation of the function which is calibrated.BJBS
Calibration Function:
Pulse repetition
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Ähnlich Pulse Generators

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken