Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Uninterruptible Power Supply				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						800.0 millimeters 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1400.0 millimeters 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1000.0 millimeters 					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Apc silcon 40kw 208v ups					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						15000.0 meters					
				 
							
					
						MRC:
						The number of input alternating current phase(s).ANPM
					 
					
						Input Phase:
					
					
						Three single operating power rqmt					
				 
							
					
						MRC:
						The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
					 
					
						Frequency Regulation Percent:
					
					
						3.0 single power output					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						208.0 ac pounds per hour wet single operating power rqmt					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						40.0 ac kilovolts  single power output					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
					 
					
						Output Frequency Rating:
					
					
						50.0 hertz  single power output and 60.0 hertz  single power output					
				 
							
					
						MRC:
						The rated output power that an item can safely consume or provide,measured in watts.BGQR
					 
					
						Output Wattage Rating:
					
					
						40.0 kilowatts  single power output					
				 
							
					
						MRC:
						The output current rating at which the item is designed to operate.CWGH
					 
					
						Output Current Rating:
					
					
						40.0 ac volt-ampere  single power output					
				 
							
					
						MRC:
						The number of output alternating current phases.CWGN
					 
					
						Output Phase:
					
					
						Three single power output					
				 
							
					
						MRC:
						The output waveform of the current at the output terminals.CWGS
					 
					
						Output Waveform And Current Type:
					
					
						Full wave rectified sine wave ac single power output					
				 
							
					
						MRC:
						The power supply operational efficiency when connected to an alternate current power line.CWWY
					 
					
						Power Supply Efficiency Line:
					
					
						95.0