Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Noncrystal Controlled Oscillator				
			 
			
							
										
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Moisture proof and salt spray resistant and shock resistant and vibration					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-40.0/+71.0 degrees celsius					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Irregular					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The means by which the item is operated or controlled.ALBM
					 
					
						Operating Control Method:
					
					
						Automatic					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Mechanical					
				 
							
					
						MRC:
						Indicates the type of control.AQZF
					 
					
						Control Type:
					
					
						Remote					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						15.0  1st voltage err-100					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						28.0  4th voltage err-100					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						-15.0  2nd voltage err-100					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
					 
					
						External Dc Operating Voltage In Volts:
					
					
						-65.0  3rd voltage err-100