Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Epoxy resin surface
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Interfere Filter				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						1.937 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
					 
					
						Body Outside Diameter:
					
					
						0.281 inches 					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms blank					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms blank					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						0.58 blank					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						800.0 millivolts ac blank					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance blank					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 clamp					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 wire loop input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 wire loop output 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						8.26 volts ac blank					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
					 
					
						Body Material:
					
					
						Metal					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Round terminal/terminals on opposite surfaces