Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
sm-d-349276
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
005421331

Informationen zum Teil
Circuit breaker overload protectiion w/spark gap and neon lamps to protect meter; ammeters has multipliers of 1, 10, 100 and 1000 to increase range to50, 000 ua, voltage doubler type circuitw/high voltage section immersed in oil; either plus or minus output terminal may be connected to guard to form/coldguard circuit; incl 1 test set no. Ts-928/u, 1 cable assembly, power, electrical, 50 ft lg and 1 lead electrical 5 ft lg

NSN
Nationale Bestandsnummer:
6625-00-542-1331 6625005421331
TXT
Beschreibung:
Insulation Breakdown Test Set
INC
INC
Artikelname-Code:
16408
INC
COM
Beachtung:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
19.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.500 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Dc
MRC:
An indication of the type of meter.ANTH
Meter Type:
Ammeter and voltmeter
MRC:
The number of meters provided.ANTJ
Meter Quantity:
2
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+40.0 kilovolts and +0.0/+50.0 microamps
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
Between 400.000 volts and 500.000 volts
MRC:
Indicates the type of indicator used to show a leakage condition.AQYK
Leakage Indicator Type:
Meter
MRC:
The number of alternating current phases.FAAZ
Phase:
Single