Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Pump unit, centrifugal
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Centrifugal Pump Unit				
			 
			
										
					
						MRC:
						The number of intake connections included on the item.AAYT
					 
					
						Intake Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Water,  fresh					
				 
							
					
						MRC:
						The number of pumps incorporated in the item.AENC
					 
					
						Pump Quantity:
					
					
						1					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Swimming pool					
				 
							
					
						MRC:
						The maximum rated capacity delivered by the item.AHYV
					 
					
						Maximum Discharge Flow Rate:
					
					
						86.0 gallons per minute					
				 
							
					
						MRC:
						The vertical distance from the level of supply to the center of the pump.AHYY
					 
					
						Suction Lift:
					
					
						10.000 feet					
				 
							
					
						MRC:
						The position in which the pumping element/s/ is designed to operate.AHZA
					 
					
						Pumping Element Operating Position:
					
					
						Horizontal					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						115.0					
				 
							
					
						MRC:
						Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
					 
					
						Special Features:
					
					
						Designed for above ground and on ground swimming pools, self priming