Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
st5m1537-003
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Nonwire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical servo mounted
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
1.3125 inches
MRC:
The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
Pilot Length:
0.0620 inches
Undercut Diameter:
1.312 inches
Undercut Width:
0.0730 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.437 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.125 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.250 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.725 inches
Mounting Lip Diameter:
1.4370 inches
Mounting Lip Depth:
0.0930 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
Effective Electrical Rotation In Deg Angular Rotation:
350.0
MRC:
The maximum amount of turning force required to initiate the actuator movement.AEFK
Maximum Starting Torque:
0.20 inch-ounces
MRC:
The eccentricity of the shaft diameter with respect to the rotational axis of the shaft,measured at a specified distance from the end of the shaft,when the body of the item is held fixed and the shaft is rotated with a specified load applied radially to the shaft.AEFZ
Shaft Runout:
0.001 inches
MRC:
The perpendicularity of the mounting surface,with respect to the rotational axis of the shaft,and measured on the mounting surface at a specified distance from the outside edge of the mounting surface,when the shaft is held fixed and the body of the item is rotated with specified loads applied radially and axially to the body of the item.AEGA
Lateral Runout:
0.002 inches
MRC:
The eccentricity of the pilot diameter with respect to the rotational axis of the shaft and measured on the pilot diameter when the shaft is held and the body of the item is rotated while a specified load is applied radially to the body.AEGB
Pilot Diameter Runout:
0.00100 inches
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Radially positioned over more than half the circumference
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
5.0 kilohms single section
MRC:
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
Rotary Actuator Travel In Angular Deg:
360.0
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.05/+0.05 single section
MRC:
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
125.0 single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
2.0 free air single section
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
Single section independent linearity
MRC:
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
Fixed Tap Quantity Per Section:
1 single section
MRC:
The limits of permissible variation from the rated value of the location of a tap per section.CRKS
Tap Location Tolerance Per Section:
-10.0/+10.0 ohms single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-10.0/+10.0 single section
MRC:
The feature that controls the actuator travel.CRSX
Actuator Travel Control Feature:
Continuous motion
MRC:
Indicates the location of a tap relative to the counterclockwise terminal per section,expressed in ohms.CSBW
Tap Location From Ccw Terminal Per Section In Ohms:
2500.0 single section
MRC:
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
Function Characteristic Per Section:
Single section linear
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
25.0 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 turret