Teilenummer:
surt6000rmxlt
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Apc smart ups rt 6000va rm 208v
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
26.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.000 inches
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz single operating power rqmt and 60.0 hertz single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz single power output and 60.0 hertz single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+32.0/+104.0 degrees fahrenheit
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
4200.0 watts single power output
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
5.3
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Includes cd with software, rack mounting support rails, smart ups signalling rs-232 cable, user manual; output power capacity and maximum configurable power 4200 watts / 6000 va; output voltage 208 v; output voltage note configurable for 208 or 240 output voltage; efficienty at full load 92.00 pct; output voltage distortion less than 3 pct; output frequency, sync to mains, 50/60 hz porm 3 hz user adjustable porm 0.1; crest factor 3: 1; waveform type sine wave; output connections nema l6-20r, 2 and nema l6-30r, 2; input bypass internal bypass, automatic and manual; cord length 10 feet; input voltage 160-280 v; input voltage adjustable for mains operation 100-280 v; other input voltages 240; battery type maintenance free sealed lead-acid battery with suspended electrolyte, leakproof; included battery modules 2; typical recharge time 2.5 hrs; replacement battery rbc44; rbcquantity type 1; typical back up time at half load 15.8 min, 2100 watts