Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Requested name: shield continuitytest set; may be hand-held or used withthe cross-bar
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Cable Shield Resistance Test Set
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Two probes attached to a cable; transformer; probe extension cable; groundwire; supporting cross-bar
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Cable shield continuity faults; bond and ground connections
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Locates and analyzes telephone cable shield continuity faults and testsquality of bond and ground connectionsat cable vaults, manholes, cross connectboxes, pedestals, and aerial cable