All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
tcle2hw90
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
001364424

Informationen zum Teil
1st end also unthreaded external accomodating 0.875 in. Od tube and 2nd end accomodating 0.750 in. Od tube

NSN
Nationale Bestandsnummer:
4820-00-136-4424 4820001364424
TXT
Beschreibung:
Expansion Valve
INC
INC
Artikelname-Code:
05493
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" or "adqn" if flanged one or two ends
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 22
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.625 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Unthreaded internal tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Socket
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACMP
Second End Outside Diameter Tube Accommodated:
0.500 inches
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Brass
MRC:
None.ADQM
First Connection Face To Centerline Distance:
1.188 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Cage
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Brass and steel, corrosion resisting
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
60.000 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
3.000 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.625 inches
MRC:
Indicates the type of control by which the valve is expanded.AFKK
Valve Expansion Control Type:
Thermostatic
MRC:
A designation of the evaporator temperature range at which the valve is designed to operate.AFKL
Valve Evaporator Tempurature Range Designation:
Low
MRC:
An indication of whether or not a device is included that throttles or stops the flow of liquid,gas,and the like,through the valve when evaporator suction pressure reaches the maximum pressure setting.AFKM
Valve Pressure Limiting Device:
Included
MRC:
The setting at which the valve pressure limiting device is designed to operate.AFKN
Valve Pressure Limiting Device Setting:
90.0 pounds per square inch absolute
MRC:
Indicates the type of transfer agent contained in the thermostatic bulb which reacts to temperature change.AFKQ
Bulb Media Type:
Refrigerant 22
MRC:
The means utilized to hold the bulb in position.AFKR
Bulb Mounting Method:
Clamp
MRC:
Indicates whether the equalizer location is internal,external,or both.AFKU
Valve Equalizer Location:
External
MRC:
Indicates the type of connection in the valve body for connecting the equalizer line.AFKV
Valve Equalizer Connection Type:
Solder tube
MRC:
The length of a straight line which passes through the center of the valve equalizer connection,and terminates at the circumference.AFKW
Valve Equalizer Connection Diameter:
0.250 inches
MRC:
The capacity of the item as rated by industry,expressed in british thermal units /btu/ of refrigeration per hour.AGUB
Refrigeration Capacity In Btu Per Hour:
24.0