Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						tdh8050-2001					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electromagnetic Relay				
			 
			
										
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Dustproof					
				 
							
					
						MRC:
						The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
					 
					
						Fragility Factor:
					
					
						Moderately rugged					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Control, platf					
				 
							
					
						MRC:
						The number of individual /not electrically connected/ windings.AKDX
					 
					
						Winding Quantity:
					
					
						1					
				 
							
					
						MRC:
						The purpose for which the item is designed.AKSL
					 
					
						Purpose For Which Designed:
					
					
						General					
				 
							
					
						MRC:
						The number of coils included on the item.APCN
					 
					
						Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 plug-in terminal single mounting facility					
				 
							
					
						MRC:
						Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
					 
					
						Storage Type:
					
					
						General purpose warehouse					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
					 
					
						Nonpile-up Main Contact Arrangement:
					
					
						2 pole,  double throw,  one position momentary					
				 
							
					
						MRC:
						The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
					 
					
						Time Delay:
					
					
						2.00 seconds  fixed operate time					
				 
							
					
						MRC:
						The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
					 
					
						Operating Voltage Rating And Type At Specificationified Temp:
					
					
						20.0 volts dc 25 degrees celsius single winding					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						10.0 amperes ac resistive load