Teilenummer TJ12K3250

Safety Relief Valve

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
tj12k3250
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
007287400
NSN
Nationale Bestandsnummer:
4820-00-728-7400 4820007287400
TXT
Beschreibung:
Safety Relief Valve
INC
INC
Artikelname-Code:
05488
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand 2nd end
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand 1st end
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The means of closing the item when inlet pressure decreases.ADSU
Disk Loading Method:
Spring
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
10.0 gallons per minute
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
300.0 degrees fahrenheit single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain (pipe) 2nd end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain, optional en (pipe) 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external pipe 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal pipe 1st end
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Pressure tight outlet side
MRC:
The minimum to maximum pressures at which the item may be set to open.CQCY
Adjustable Pressure Range:
+40.0/+400.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
400.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.500 inches 1st end
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.500 inches 2nd end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel body
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel seat
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water-oil-gas single response
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Cadmium
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight through note: to be used for valve bodies of separable sections.
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt 2nd end
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt 1st end

Ähnlich Safety Relief Valves

« Nonpowered Valves {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken