Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Radar Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
12.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
19.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 1600.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Pick-up antenna; rf cable assembly; cord; cord; adapter connector; adapter connector; adapter; instruction books
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 1 and 1 and 2
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Buaer; usaf; buships; buaer; usaf; usaf; usaf; buships
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
At-68/up model no. And cg-530 model no. And cg-92a/u model no. And cx-337/u model no. And ug-446/u model no. And ug-397/u model no. And ug-273/u model no.
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Alignment of beacon equipment, radar systems, and rf circuits. Measurement of power, measurement of frequency
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Signal generator; range' 8500 to 9600 mc frequency meter, range' 8470 to 9630 mc rf power monitor and reference level indicator scale graduation in increments of 15 ua from 150 to 0 to 150 to be interpreted as increments of 0.05 mw from 2 to 0 to 2 mw
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
14.000 inches
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
W/spares