Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						True rms ac with read out in volts or db;  ac or ac + dc measurement;  autoranging;  selectable dbm reference impedance;  analog display for peak/null adjustments;  rear panel linear analog output;  relative db measurements;  full frequency range 2 hz to 20 mhz;  weight 5.44 lbs
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Voltmeter				
			 
			
										
					
						MRC:
						The type of electrical circuit in which the item is designed to be used.AACT
					 
					
						Circuit Current For Which Designed:
					
					
						Ac					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						12.900 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						4.300 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						8.000 inches 					
				 
							
					
						MRC:
						The number of scale divisions.ABWG
					 
					
						Scale Division Quantity:
					
					
						8 single indicator single range					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						Between 50.0 hertz and 400.0 hertz 					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						An/urc-117 ground wave emergency network (gwen)					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Digital display and dial w/pointer					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Rack					
				 
							
					
						MRC:
						The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
					 
					
						Frequency Response Range:
					
					
						+0.050/+200.000 kilohertz					
				 
							
					
						MRC:
						The hue or tint of the background.AQFY
					 
					
						Background Color:
					
					
						Black single indicator all ranges					
				 
							
					
						MRC:
						The source of power which provides the energy required for the operation of the item.AWZJ
					 
					
						Power Source:
					
					
						External					
				 
							
					
						MRC:
						Indicates the type of display provided.BFQN
					 
					
						Display Type:
					
					
						Light emitting diode					
				 
							
					
						MRC:
						The number of digits displayed.BFQP
					 
					
						Display Digit Quantity:
					
					
						5					
				 
							
					
						MRC:
						Indicates the type of graduations provided on the scale.BHDC
					 
					
						Scale Graduation Type:
					
					
						Linear single indicator all ranges					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2.0 millivolts single indicator 1st range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+2.0 volts single indicator 4th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 millivolts single indicator 2nd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+20.0 volts single indicator 5th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 millivolts single indicator 3rd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+200.0 volts single indicator 6th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+700.0 volts single indicator 7th range					
				 
							
					
						MRC:
						The means provided for selecting a scale.BLSB
					 
					
						Scale Selection Method:
					
					
						Switch					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm .5% of reading 4th range single indicator 4th range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm .5% of reading 5th range single indicator 5th range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm .5% of reading 6th range single indicator 6th range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm .5% of reading 7th range single indicator 7th range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm .5% of reading 3rd range single indicator 3rd range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 1 % of reading 2nd range single indicator 2nd range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 2 % of reading 1st range single indicator 1st range					
				 
							
					
						MRC:
						The hue or tint of the display.CTQH
					 
					
						Display Color:
					
					
						White single indicator all ranges					
				 
							
					
						MRC:
						The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
					 
					
						Circuit Attachment Method And Quantity:
					
					
						1 probe,  direct contact					
				 
							
					
						MRC:
						The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
					 
					
						Operating Voltage Rating In Volts:
					
					
						100.0 ac  and 120.0 ac  and 220.0 ac  and 240.0 ac 					
				 
							
					
						MRC:
						The type and/or standard interface system with which the item is compatible.CTWZ
					 
					
						Interface Compatibility:
					
					
						Ieee-488					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single					
				 
							
					
						MRC:
						The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
					 
					
						Functional Classification:
					
					
						Aa-1.1					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						D1 rectangular or square