Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Band Pass Filter				
			 
			
										
					
						MRC:
						The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
					 
					
						Reference Frequency Per Function:
					
					
						72.0 megahertz blank					
				 
							
					
						MRC:
						The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
					 
					
						Input Impedance Per Function W/load:
					
					
						50.0 ohms blank					
				 
							
					
						MRC:
						The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
					 
					
						Output Impedance Per Function W/source Across Input:
					
					
						50.0 ohms blank					
				 
							
					
						MRC:
						A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
					 
					
						Mounting Facility Screw Thread Series Designator:
					
					
						Unc					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 threaded hole					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 connector,  receptacle input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 connector,  receptacle output 2nd function					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.164 inches					
				 
							
					
						MRC:
						The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
					 
					
						Frequency Band Width Per Function:
					
					
						48.00 megahertz blank and 95.00 megahertz blank