Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Power Autotransforme Transformer				
			 
			
										
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						400.0 hertz  single component					
				 
							
					
						MRC:
						The relationship of the phase input to the phase output of an alternating current.ACZC
					 
					
						Input-output Phase Relationship:
					
					
						Single phase to single phase single component					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						5.438 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						5.125 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						5.500 inches 					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						4 single group					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Slot single group					
				 
							
					
						MRC:
						The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
					 
					
						Winding Function And Quantity:
					
					
						1 primary,  fixed autotransformer type single component					
				 
							
					
						MRC:
						The amount of operating current for which the winding is designed.CRBZ
					 
					
						Winding Operating Current:
					
					
						9.5 amperes ac  single component single primary output					
				 
							
					
						MRC:
						The maximum power for which the winding of the item is rated.CRMJ
					 
					
						Winding Power Rating:
					
					
						3.9 kilovolt-amperes single component single primary output					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						7 threaded stud