Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Differential Transmitter Synchro
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, stainless
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Standard round c
MRC:
The length of a straight line which passes through the center of a shoulder,and terminates at the circumference.AAVH
Shoulder Diameter:
Between 0.9995 inches and 1.0000 inches
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
Between 0.6245 inches and 0.6250 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 2.1660 inches and 2.1860 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
Between 1.0570 inches and 1.0650 inches
MRC:
A measurement of the smallest dimension of a flange,in distinction from length or width.ABKU
Flange Thickness:
0.0930 inches
Undercut Diameter:
Between 0.9700 inches and 0.9800 inches
Undercut Width:
0.0620 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.1870 inches single shaft and 0.1873 inches single shaft
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.4750 inches single shaft and 0.4950 inches single shaft
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
11
MRC:
The value of the primary excitation voltage for which the stator is rated,expressed in volts.AJSN
Stator Input Voltage Rating In Volts:
11.8
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The magnitude part /z/ of the rotor impedance with the stator open /zro/,expressed in ohms.AJTG
Zro Impedance Magnitude In Ohms:
Between 364.50 and 445.50
MRC:
The angle part /o/ of the rotor impedance with the stator open /zro/,expressed in degrees.AJTH
Zro Impedance Angle In Deg:
Between 77.00 and 83.00
MRC:
The magnitude part /z/ of the stator impedance with the rotor open /zso/,expressed in ohms.AJTJ
Zso Impedance Magnitude In Ohms:
Between 283.50 and 346.50
MRC:
The angle part /o/ of the stator impedance with the rotor open /zso/,expressed in degrees.AJTK
Zso Impedance Angle In Deg:
Between 79.00 and 85.00
MRC:
The opposition that the rotor offers to the flow of the direct current,expressed in ohms.AJTS
Rotor Dc Resistance In Ohms:
40.00
MRC:
The opposition that the stator offers to the flow of direct current,expressed in ohms.AJTT
Stator Dc Resistance In Ohms:
60.00
MRC:
The difference between the phase time of two or more voltages or currents of the same frequency,at the same instant of time,expressed in degrees.AJVF
Phase Shift Angle In Deg:
5.000 input to output
MRC:
The maximum voltage,without harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVG
Maximum Fundamental Null Voltage In Millivolts Per Volt:
10.00 output
MRC:
The maximum voltage,including harmonics,induced in the secondary circuit at the null angle rotor position,expressed in millivolts per volt.AJVH
Maximum Total Null Voltage Output In Millivolts Per Volt:
30.00
MRC:
The limits of permissible deviation in angular arc error from electrical zero,expressed in minutes.AJVL
Electrical Error Angular Range In Minutes:
-5.5/+5.5
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at minus 55 degrees celsius.AJVS
Actuator Friction Torque At Minus 55 Deg Celsius:
40.00 centimeter-grams
MRC:
The amount of rotary force that must be applied to the actuator to cause rotation,at plus 25 degrees celsius.AJVT
Actuator Friction Torque At Plus 25 Deg Celsius:
20.00 centimeter-grams
MRC:
The measurement taken from the bearing face to the point on the shaft where the weight /load/ is applied.AJWE
Shaft Radial Play Test Point:
0.250 inches
MRC:
The maximum shaft displacement perpendicular to the shaft axis due to reversal of a specified force applied perpendicular to the shaft axis,and measured at a specified distance from the front surface of the unit.AJWG
Shaft Maximum Radial Play:
0.0008 inches
MRC:
The axial shaft displacement due to reversal of a specified axial force,measured at the end of the shaft.AJWH
Shaft End Play:
0.0015 inches
MRC:
A measurement of the longest dimension of a pilot,in distinction from width.AJWQ
Pilot Length:
0.0590 mils and 0.0650 centimeters
Shoulder Length:
0.0590 mils and 0.0650 centimeters
Mounting Surface To Terminal End Distance:
1.6910 inches
MRC:
The eccentricity of the shaft diameter with respect to the rotational axis of the shaft,measured at a specified distance from the end of the shaft,when the body of the item is held fixed and the shaft is rotated.AJXB
Shaft Maximum Runout:
0.0010 inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Rear
Shaft Slot Depth:
0.0260 inches single shaft and 0.0360 inches single shaft
Shaft Slot Width:
0.0260 inches single shaft and 0.0360 inches single shaft
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, slotted single shaft
MRC:
The ratio of the output voltage to the input voltage at maximum coupling.CSJY
Transformation Ratio:
0.850 rotor to stator
MRC:
The force (load) applied perpendicular to the shaft axis to determine radial play.CWXK
Shaft Radial Play Determining Weight:
4.0 ounces
MRC:
The force (load) applied parallel to the shaft axis to determine end play.CWYF
Shaft End Play Determining Weight:
8.0 ounces
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 wire lead