Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
us381-1andus84132-2
Informationen zum Teil
Moisture and fungus resistant
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Voltage Regulator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.250 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.164 inches
MRC:
The center to center distance between mounting holes.ABTH
Center To Center Distance Between Mounting Holes:
0.438 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
2
MRC:
The means of attaching the item.ACUN
Mounting Method:
Threaded hole or unthreaded hole
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. Gn-58
MRC:
The means used for regulating the item.AMZD
Regulation Method:
Electromechanical
MRC:
The type of compensation provided.ANAE
Compensation Provided:
Differential cross current
MRC:
The regulated value/s/ of the item,expressed in percent.ANBD
Regulation Percent:
8.000
MRC:
Indicates the type of input current whether alternating,direct,or both.ANPJ
Input Current Type:
Ac and dc
MRC:
The input voltage rating at which the item is designed to operate,expressed in volts.ANPK
Input Voltage Rating In Volts:
425.0 and 105.0 and 6.3 and 1.4
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
48.800 watts and 3.700 watts and 15.400 watts and 0.600 watts
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Closed frame