Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Flow Switch
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -4.0 degrees fahrenheit and 125.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Line
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Connector, receptacle
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
2.0 amperes inductive load single voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point not adjustable and deactuation point not adjustable
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
2.80 actuation point gallons per minute and 2.50 deactuation point gallons per minute
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
28.0 dc at sea level single voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Liquid