Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Glass Dielect Variable Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Piston
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
2.000 inches
MRC:
The length of a straight line which passes through the center of a bushing,and terminates at the circumference.ABKH
Bushing Diameter:
0.190 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.170 inches single shaft
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.250 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.194 inches single shaft
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.469 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.250 inches
MRC:
The minimum and maximum values of the permissible change in capacitance caused by a change in temperature,in parts per million per degree celsius.AEBF
Tempurature Coefficient Of Capacitance Range In Ppm Per Deg Celsius:
-50.0/+50.0 single section
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
0.025 inches
MRC:
The ratio of capacitive reactance to resistance,expressed at 25 degrees celsius.AECJ
Quality Factor At 25 Deg Celsius:
500.0
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The physical configuration of the bushing.AXGS
Bushing Shape:
Round, keyed
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at 25 degrees celsius.AXGT
Insulation Dc Resistance At 25 Deg Celsius:
1000000.0 megohms
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 bushing, press-fit
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -40.0 degrees celsius and 120.0 degrees celsius
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round single shaft
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+0.5/+0.8 single section
MRC:
The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
Nonderated Voltage Rating And Type:
500.0 dc continuous single section
MRC:
Indicates the type and number of drive(s) provided for the adjustment device.CTGR
Adjustment Device Drive Type And Quantity:
1 shaft
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 wire lead