Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Terminals come out the side of themal
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Thermal Resistor				
			 
			
										
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
					 
					
						Thread Length:
					
					
						0.880 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a terminal,in distinction from width.ABJT
					 
					
						Terminal Length:
					
					
						Between 21.500 inches and 22.500 inches 					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended by an item.AEHX
					 
					
						Maximum Power Dissipation Rating:
					
					
						1.00 milliwatts					
				 
							
					
						MRC:
						The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
					 
					
						Ambient Tempurature At Full Rated Power:
					
					
						25.0 degrees celsius					
				 
							
					
						MRC:
						A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
					 
					
						Mounting Facility Screw Thread Series Designator:
					
					
						Unc					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encapsulated					
				 
							
					
						MRC:
						The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.CGGK
					 
					
						Mounting Thread Quantity:
					
					
						16 per inch					
				 
							
					
						MRC:
						The dc resistance value measured with a power dissipation low enough that any further decrease in power will result in not more than 0.1 percent change in resistance.CQWD
					 
					
						Zero Power Resistance:
					
					
						175.500 kilohms					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value of an item from its rated zero power resistance,expressed in percent at reference temperature.CRQJ
					 
					
						Zero Power Resistance Tolerance In Percent At Reference Temp:
					
					
						-5.0/+5.0					
				 
							
					
						MRC:
						The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.CRYY
					 
					
						Mounting Facility Screw Thread Diameter:
					
					
						0.375 inches					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						19207-12380377 drawing (this is the basic governing drawing,  such as a contractor drawing,  original equipment manufacturer drawing,  etc.;  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 wire lead