Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Nonwire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical bushing mounted
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.500 inches
Mounting Bushing Length:
0.250 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.469 inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Rugged
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Rear end
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
10.0 kilohms single section
MRC:
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
120.0 single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
0.5 free air single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-20.0/+20.0 single section
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
70.0 single section