Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electrical Plug Connector				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.375 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						1.375 inches 					
				 
							
					
						MRC:
						The angle the end/s/ or legs deviate from the centerline of the inlet end,expressed in degrees.ADMW
					 
					
						Body Angle In Deg:
					
					
						90.0					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Heat resistant and salt water resistant					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the cable entrance,and terminates at the circumference.AFQJ
					 
					
						Cable Entrance Diameter:
					
					
						Between 0.295 inches and 0.585 inches 					
				 
							
					
						MRC:
						The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
					 
					
						Mating End Quantity:
					
					
						1					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
					 
					
						Contact Position Arrangement Style:
					
					
						2 single mating end					
				 
							
					
						MRC:
						An indication of whether or not the contact(s) is removable.AFQZ
					 
					
						Contact Removability:
					
					
						Nonremovable single mating end single contact grouping					
				 
							
					
						MRC:
						The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
					 
					
						Contact Maximum Current Rating In Amps:
					
					
						15.0 single mating end single contact grouping					
				 
							
					
						MRC:
						The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
					 
					
						Contact Maximum Ac Voltage Rating In Volts:
					
					
						125.0 single mating end single contact grouping					
				 
							
					
						MRC:
						The means used to prevent mismating or cross plugging of contacts.AFRN
					 
					
						Polarization Method:
					
					
						Contact					
				 
							
					
						MRC:
						The means by which the connector cable is relieved of stress and strain.AFRW
					 
					
						Connector Cable Strain Relief Method:
					
					
						Integral clamp					
				 
							
					
						MRC:
						Indicates the location of the terminal/s/ on the item.CQTM
					 
					
						Terminal Location:
					
					
						Back single mating end single contact grouping					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Screw single mating end single contact grouping					
				 
							
					
						MRC:
						The number of contacts included with the item which provides electrical connection.CXCG
					 
					
						Included Contact Quantity:
					
					
						2 single mating end single contact grouping					
				 
							
					
						MRC:
						Indicates the type of contact(s) included with the item.CXCL
					 
					
						Included Contact Type:
					
					
						Curved socket single mating end single contact grouping					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						81348-w-c-596 specification (includes engineering type bulletins,  brochures, etc.,  that reflect specification type data in specification format;  excludes commercial catalogs,  industry directories,  and similar trade publications,  reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical",  "average",  "",  etc.).					
				 
							
					
						MRC:
						The document designator of the specification or standard which established the item of supply.ZZZK
					 
					
						Specification Data:
					
					
						81348-w-c-596e government specification