Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Eaa is tank, combat, full tracked, nsn 2350-01-061-2445; motor is capable of operating during & after submergingin water to a depth of 6 ft.; max. Current is 55 amps. At 30vdc loaded to 1.5 h.P. Output; operating voltage rangeis 18-30vdc; storage temp. Range is -70.0 to +160 deg. F.; shaft end is threaded to 0.500-20unf-2a
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Direct Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
6.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
6.000 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.500 inches first end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
General purpose and splash proof and watertight
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Series wound and shunt wound
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Natural convection ventilated
Keyway Center To Shaft End Distance:
1.250 inches first end
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
A number or letter representing the size of a woodruff key.CNMK
Woodruff Key Size Designation:
405 single end
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
1650.0 volt-ampere input
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
2.240 inches first end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-25.0 operating degrees fahrenheit and 140.0 operating degrees fahrenheit
MRC:
The length of a straight line which passes through the center of a mounting facility circle,and terminates at the circumference.CWFQ
Mounting Facility Circle Diameter:
4.620 inches
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
5800.0 single no load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
55.000 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
30.0 line to line single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A11 single style single end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 receptacle