Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Oil Contamination Monitor
MRC:
A measurement of the longest dimension of the probe,in distinction from width.AEJG
Probe Length:
200.0 millimeters
MRC:
Indicates the type of presentation.AMNL
Presentation Type:
Digital display and alarm
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
2
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
232.0 pounds per square inch
MRC:
Indicates the type of voltage and the rated value for which the item is designed.BGWF
Voltage Rating And Type:
8.0 volts dc and 12.0 volts ac and 35.0 volts ac and 48.0 volts dc
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Rs232 port
MRC:
The minus and/or plus degrees of temperature the item can withstand without giving erroneous assay data.CYHE
Operating Temperature Range:
20.0 degrees celsius minus and 50.0 degrees celsius plus
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fuel/oil, hydrocarbon