Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
ws2107fl510
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
010915592

Informationen zum Teil
4.688 in. Sq flange w/hole ea corner at both ends of venturi tube

NSN
Nationale Bestandsnummer:
4140-01-091-5592 4140010915592
TXT
Beschreibung:
Tubeaxial Fan
INC
INC
Artikelname-Code:
04244
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
1.500 inches
MRC:
The direction in which the fluid is passed through the item.ADNK
Flow Direction:
Outward
MRC:
The temperature of the medium surrounding an item at which it can be operated continuously at full rated power.AEHY
Ambient Tempurature At Full Rated Power:
70.0 degrees celsius
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Terminal box
MRC:
The static pressure measured at the air flow rate specified.AJLY
Static Pressure At Specificationified Air Flow Rate:
0.0 inches of water
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 flange and 8 unthreaded hole
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Counterclockwise
MRC:
The rated capacity of air flow moved through the item.CQKX
Air Flow Rate:
120.0 cubic feet per minute
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
None.CWLX
Housing Inside Diameter:
4.517 inches
MRC:
Indicates the type of bearing/s/ provided on the prime mover drive shaft.CWLY
Prime Mover Drive Shaft Bearing Type:
Sleeve
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic blade
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Zinc alloy housing
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel housing
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Fixed