Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Thermostatic Switch
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Dusttight
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.950 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.390 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.140 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.810 inches
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
72.0 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
4.000 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.375 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Capillary tube-bulb
MRC:
The means of attaching the item.AXGY
Mounting Method:
Immersion well and threaded bushing
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
14 single threaded bushing
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches single threaded bushing
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Screw
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
10.0 amperes resistive load first voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
6.0 amperes resistive load second voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point adjustable
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
-30.00/+100.00 actuation point degrees fahrenheit
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
External actuation point knob with scale
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
120.0 ac at sea level first voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
240.0 ac at sea level second voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt single threaded bushing