Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						One fractional-horsepower motor, 115 volts, 60 cycle, single-phase, ac, used on burner atomizer
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Warm Air Furnace				
			 
			
										
					
						MRC:
						Indicates the type of mount utilized to support the item.AAXX
					 
					
						Mounting Type:
					
					
						Floor surface,  free standing,  ducted					
				 
							
					
						MRC:
						Indicates the heat medium type for which the unit is designed.ABAM
					 
					
						Heat Medium Type:
					
					
						Air					
				 
							
					
						MRC:
						The number of heat outlets included on the item.ABAW
					 
					
						Heat Outlet Quantity:
					
					
						1					
				 
							
					
						MRC:
						The direction in which the heat is discharged from the item.ABAX
					 
					
						Heat Delivery Direction:
					
					
						Vertical					
				 
							
					
						MRC:
						Indicates the type of outlet(s) provided for the discharge of heat.ABAY
					 
					
						Heat Discharge Outlet Type:
					
					
						Stationary					
				 
							
					
						MRC:
						Indicates the device/s/ provided for the purpose of directing the flow of heat.ABAZ
					 
					
						Heat Directing Device:
					
					
						Adjustable louver					
				 
							
					
						MRC:
						The mechanism used for air circulation.ABBA
					 
					
						Air Circulation Device:
					
					
						Propeller fan					
				 
							
					
						MRC:
						The different speeds at which the item may be operated.ABBB
					 
					
						Speed Adjustments:
					
					
						Single speed					
				 
							
					
						MRC:
						Indicates the type of air the item is designed to circulate.ABBE
					 
					
						Circulated Air Type:
					
					
						Heated					
				 
							
					
						MRC:
						Indicates the type of air filter included on the item.ABBF
					 
					
						Air Filter Type:
					
					
						Replaceable preformed					
				 
							
					
						MRC:
						Indicates the location of the flue connection.ABFH
					 
					
						Flue Connection Location:
					
					
						Any accpetable					
				 
							
					
						MRC:
						Indicates the type of current whether alternating,direct,or both.ACDC
					 
					
						Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of device which controls the operation of the item.ALYC
					 
					
						Operating Control Type:
					
					
						Thermostatic					
				 
							
					
						MRC:
						The electrical current rating,expressed in amperes.AMPS
					 
					
						Current Rating In Amps:
					
					
						1.5					
				 
							
					
						MRC:
						Indicates the type of heating element provided.BDXJ
					 
					
						Heating Element Type:
					
					
						Burner					
				 
							
					
						MRC:
						The means used for purposes of igniting.BLJC
					 
					
						Ignition Method:
					
					
						Pilot					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
					 
					
						Inclosure Material:
					
					
						Steel					
				 
							
					
						MRC:
						The rate of heat delivery of the item.CQXD
					 
					
						Heat Delivery Rate:
					
					
						125000.0 british thermal unit					
				 
							
					
						MRC:
						The means by which the fuel is fed to the item.CSGC
					 
					
						Fuel Feed Method:
					
					
						Gravity					
				 
							
					
						MRC:
						The total electrical voltage.ELEC
					 
					
						Voltage In Volts:
					
					
						230.0					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0					
				 
							
					
						MRC:
						Indicates the type of fuel(s) for which the item is designed.FUEL
					 
					
						Fuel Type:
					
					
						Fs no. 2 burner fuel oil					
				 
							
					
						MRC:
						A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
					 
					
						Quantity:
					
					
						1					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
					 
					
						Surface Treatment:
					
					
						Enamel					
				 
							
					
						MRC:
						The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
					 
					
						Specification Or Standard:
					
					
						1 type and a style and 120 size and 1 group and lo, burner class