Teilenummer WW8676331

Steam Turbine

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
ww8676331
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
001866551
NSN
Nationale Bestandsnummer:
2825-00-186-6551 2825001866551
TXT
Beschreibung:
Steam Turbine
INC
INC
Artikelname-Code:
04569
MRC:
The gage pressure of the expanded steam after driving the prime mover.AAYP
Exhaust Pressure:
40.60 pounds per square inch gage
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Horizontal
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise
MRC:
The term used to describe the ahead (forward) stage design of the item.AXGF
Ahead Stage Design:
Impulse
MRC:
The rated horsepower of the item in ahead /forward/ motion,at specified revolutions per minute.AXLF
Ahead Rated Horsepower At Specificationified Rpm:
14030 shaft hp at 6015 rpm
MRC:
The number of ahead /forward/ impulse stages employed by the item.AXNY
Ahead Impulse Stage Quantity:
12
MRC:
The number of rows of rotating blades on the ahead /forward/ impulse stage.AXPG
Ahead Impulse Stage Rotation Blade Row Quantity:
13
MRC:
The number of rows of stationary blades on the ahead /forward/ impulse stage.AXRC
Ahead Impulse Stage Stationary Blade Row Quantity:
1
MRC:
Indicates the ahead flow type of the item.AXRF
Ahead Flow Type:
Single
MRC:
The initial ahead /forward/ steam gage pressure required to operate the item.AXRL
Ahead Initial Steam Gage Pressure:
525.0 pounds per square inch
MRC:
The initial ahead (forward) steam temperature required to operate the item.AXRN
Ahead Initial Steam Temp:
825.0 degrees fahrenheit
MRC:
An indication of the assembled form in which the reduction gear is supplied.AXRQ
Reduction Gear Assembled Form:
Separate
MRC:
An indication of the assembled form in which the lube oil cooler is supplied.AXSA
Lube Oil Cooler Assembled Form:
Separate
MRC:
An indication of the assembled form in which the throttle valve is supplied.AXSC
Throttle Valve Assembled Form:
Integral