Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Junction pattern arrangement: npn
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Transistor
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.570 inches and 0.620 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 0.170 inches and 0.190 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 0.380 inches and 0.440 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Jet ranger ch139 distance measuring equipment
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
An indication of the internal basic form of the item.ALAS
Internal Configuration:
Junction contact
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
The chemical compound or mechanical mixture properties of which the semiconductor is fabricated.CTMZ
Semiconductor Material:
Silicon
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
75.0 collector to emitter voltage/static/base open and 5.0 emitter to base voltage, static, collector open and 75.0 collector-to-emitter, substaining voltage, base open-circuited and 1.0 collector to emitter saturation voltage and 1.0 base to emitter saturation voltage
MRC:
The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
Current Rating Per Characteristic:
10.00 microamperes zero-gate-voltage source current preset and 100.00 microamperes zero-gate-voltage source current major
MRC:
The ratio of the input electrical signal to the output electrical signal at specified operating conditions.CTRK
Transfer Ratio:
20.0 static forward current transfer ratio, common-emitter
MRC:
The maximum temperature at which the item is designed to operate at each measurement point.CTSG
Maximum Operating Tempurature Per Measurement Point:
150.0 degrees celsius junction
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 printed circuit