Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
0a350-2
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
010066100

Informationen zum Teil
Ranges: 0 to .01 ppm, 0 to .1 ppm, 0 to .5 ppm, 0 to 1 ppm, 0 to 5 ppm, 0 to 10 ppm; min detectable sensitivity .0005 ppm; relative humidity range 10 to 95 pct.; precision porm 2 pct.; operational period 7 days unattended; ambient temp range 10 to 40 degrees c; measures concentration of ozone in ambient air by photometrically monitoring the chemiluminescence resulting from the reaction of ethylene gas with ozone; built-in calibration system

NSN
Nationale Bestandsnummer:
6630-01-006-6100 6630010066100
TXT
Beschreibung:
Oxygen Analyzer
INC
INC
Artikelname-Code:
27944
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
20.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
An indication of whether or not a carrying handle is included.AXQG
Carrying Handle:
Not included
MRC:
An indication of whether or not a corrosion resistant feature is included.AYCM
Corrosion Resistant Feature:
Included
MRC:
The minimum and maximum values representing the detection rate of the item,expressed in percent.BNKD
Detection Range In Percent:
+0.0/+100.0
MRC:
Indicates the type of analysis cell provided.BNKF
Analysis Cell Type:
Rapid response
MRC:
Indicates the type of sample provided.BNKH
Sample Type:
Flowing
MRC:
The time required for an item to respond to a specific condition.BNKJ
Response Time:
15.0 seconds
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0