Teilenummer 4934A-001-J01-916

Data Transmission Line Test Set

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
4934a-001-j01-916
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
014651965

Informationen zum Teil
Transmission impairment measuring set (tims); rs-232 remote; flash memory; incl front panel cover, power cord; 2 test cord; op manual; op temp 0 to 40 degrees c; w/opt 001 built in rechargable battery and charger; opt j01 tone generator 820 hz holding tone; opt 916 service manual for j01 opt

NSN
Nationale Bestandsnummer:
6625-01-465-1965 6625014651965
TXT
Beschreibung:
Data Transmission Line Test Set
INC
INC
Artikelname-Code:
45644
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
0.280 millimeters
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
220.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 66.0 hertz
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
355.0 millimeters
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Alternate operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Diagnoses telephone line problems; helps commission new lines
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
105.0 millimeters

Ähnlich Data Transmission Line Test Sets

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken