Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Interfere Filter				
			 
			
										
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						2.160 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.700 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						1.150 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						1.080 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-55.0/+125.0 degrees celsius					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 1st radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 1st radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						50.0 2nd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						50.0 1st radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						0.000001 1st radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						0.000001 2nd radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						2.5 volts ac 1st radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						2.5 volts ac 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 1st radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 plug-in					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 connector,  receptacle ground 3rd function and 1 tab,  solder lug ground 3rd function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 connector,  receptacle input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 tab,  solder lug output 2nd function					
				 
							
					
						MRC:
						The maximum alternating current root mean square voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CQDZ
					 
					
						Maximum Dielectric Withstanding Ac Rms Voltage:
					
					
						500.0 volts at sea level					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						250.0 volts ac 1st radio interference 1st function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						250.0 volts ac 2nd radio interference 2nd function					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
					 
					
						Body Material:
					
					
						Metal					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular terminal/terminals on opposite surfaces