Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Meter Movement Relay				
			 
			
										
					
						MRC:
						The number of terminals for providing electrical connection to the item.AARA
					 
					
						Terminal Quantity:
					
					
						2					
				 
							
					
						MRC:
						Indicates the type of terminals for providing electrical connection to the item.AARB
					 
					
						Terminal Type:
					
					
						Pigtail					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
					 
					
						Mounting Flange Width:
					
					
						2.812 inches 					
				 
							
					
						MRC:
						The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
					 
					
						Case Material:
					
					
						Metal					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Explosion proof and hermetically sealed					
				 
							
					
						MRC:
						The pattern or arrangement that describes the mounting configuration of the item.ALGC
					 
					
						Mounting Configuration:
					
					
						Three no. 4-40 mtg studs spaced 120 degrees apart on a 1-1/4 in. Radius					
				 
							
					
						MRC:
						The value(s) of potential for which the item is rated.AMSE
					 
					
						Voltage Rating:
					
					
						125.0 volts 					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
					 
					
						Main Contact Arrangement:
					
					
						1 pole,  single throw,  both positions maintained					
				 
							
					
						MRC:
						Indicates the type of current used by the main contact/s/.APEB
					 
					
						Main Contact Current Type:
					
					
						Dc					
				 
							
					
						MRC:
						The current rating of the main contact/s/.APEC
					 
					
						Main Contact Current Rating:
					
					
						25.0 amperes 					
				 
							
					
						MRC:
						Indicates the type of current used in the meter movement.APGN
					 
					
						Meter Movement Current Type:
					
					
						Dc					
				 
							
					
						MRC:
						The amount of voltage required to operate the meter movement,expressed in volts.APGP
					 
					
						Meter Movement Voltage In Volts:
					
					
						50.000 					
				 
							
					
						MRC:
						An indication of the minimum and maximum amount of current used in the meter movement.APGR
					 
					
						Meter Movement Current Range:
					
					
						+0.0/+50.0 microamperes					
				 
							
					
						MRC:
						Indicates the type of mount utilized to support the meter.APMR
					 
					
						Meter Mounting Type:
					
					
						Flush					
				 
							
					
						MRC:
						An indication of the specific condition that causes the contacts to close.APMT
					 
					
						Contact Closing Condition:
					
					
						Decrease value					
				 
							
					
						MRC:
						An indication of whether or not the reset facilities are provided.APNR
					 
					
						Reset Facility Feature:
					
					
						Not provided					
				 
							
					
						MRC:
						A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
					 
					
						Meter Depth Behind Mounting Flange:
					
					
						1.625 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
					 
					
						Meter Body Diameter:
					
					
						2.125 inches